Skip to content
HELVION Biosciences
HELVION Biosciences 1
Sign in Order now

Paperwork.

What comes with every delivery — and what you can request beforehand.

Before purchase

On request.

Safety data sheet
PDF, German and English
Specification sheet
Target values and test methods
Declaration of origin
Not of animal origin
Specimen certificate
Example batch, redacted

Tell us which document you need — we send it the same working day.

Request a document

With the delivery

Batch-specific.

Certificate of analysis
Per batch
Batch conformity declaration
Per batch
Chromatogram
RP-HPLC, to scale
Order now

What the certificate states.

The certificate of analysis carries the same batch number as the label on the vial. If a different number appears there, it is not the certificate for your goods — in that case please contact us before using the batch.

Purity (RP-HPLC, 220 nm)
Measured value in percent
Identity (ESI-MS)
Measured mass against nominal mass
Peptide content (AAA)
Measured value in percent
Water content (Karl Fischer)
Measured value in percent
Residual solvents (GC)
Measured value per solvent
Release and expiry date
Dates of the batch

Weighing and
dilution.

Two calculators for the day the vial is on the bench. The molecular mass is that of GLP-5; everything else you enter.

Amount to weigh

Mass (g) = concentration (mol/L) × volume (L) × molecular mass (g/mol)

g/mol

—

Dilution

Concentration (stock) × volume (stock) = concentration (target) × volume (target)

—

The calculators are an aid, not a release. The certificate of analysis for the batch supplied is what governs.